Bosch Refrigerator Error Codes: Full List and Fixes

Bosch refrigerators use a series of fault codes to communicate problems with sensors, fans, and the cooling system. This guide covers every common Bosch refrigerator error code, explains what is happening inside your appliance, and gives you the at-home fix to try before calling a technician.

Bosch Refrigerator Error Code Table

Code Meaning Fix
E1 Fridge temperature sensor fault Unplug 5 min; replace sensor if recurring
E2 Freezer temperature sensor fault Defrost; replace freezer sensor
E3 Defrost heater / sensor fault Manual defrost; call Bosch service
E4 Evaporator fan motor fault Defrost; replace fan motor
E5 Condenser fan motor fault Clean condenser; check fan
E7 Communication error Unplug 10 min; call Bosch service
d1 / d2 Door alarm (door left open) Close door firmly; check door seal
F0 Control board fault Power reset; call Bosch service
H1 High fridge temperature alarm Check door seal; reduce load
H2 High freezer temperature alarm Check door seal; check compressor

Most Common Bosch Error Codes Explained

E1 / E2 — Temperature Sensor Faults

Bosch uses E1 for the fridge sensor and E2 for the freezer sensor. These sensors tell the control board when to start and stop the compressor. A fault here means the fridge cannot maintain the correct temperature. You may notice food spoiling faster or items in the fridge compartment freezing.

Fix: A 5-minute power reset clears transient faults. If the code persists, the sensor costs ₹400–₹800 and a Bosch-authorised technician can replace it quickly.

E3 — Defrost Heater or Sensor Fault

E3 is a defrost system fault. Without a functioning defrost cycle, the evaporator ices over within days, causing both compartments to lose cooling. Manual defrost (unplug, doors open, 24 hours) is the first step. After that, the heater or sensor needs professional inspection.

E4 — Evaporator Fan Fault

The evaporator fan distributes cold air. When it fails — usually due to ice jamming the blades — only the immediate area around the evaporator stays cold. Defrost manually and reset. If the fan still does not run, the motor needs replacement (₹900–₹1,800).

d1 / d2 — Door Open Alarm

Bosch triggers a door alarm after the door has been open for approximately 60 seconds. Check that nothing is blocking the door from closing fully, inspect the rubber door gasket for splits or gaps, and press firmly to ensure the magnetic seal engages.

H1 / H2 — High Temperature Alarms

H1 (fridge) and H2 (freezer) appear after a power outage or when the cooling system cannot maintain safe temperatures. After power is restored, allow 4–6 hours for temperatures to stabilise. If the alarm persists beyond 6 hours, the cooling system needs inspection.

When to Call Bosch Service

  • E7 (communication) or F0 (control board) — always needs authorised service
  • Error code returns after power reset and defrost
  • H1 or H2 alarm persists more than 6 hours after power restoration

Bosch India service: 1800-266-1880